Decide whether the summit keeps the borrowed ultrasonic sensor or buys its own: the loan ends in April, and the lender’s USA-2 firmware cannot report its heater’s state to the logger

kind
task
state
active
weight
pressing
size
xs
updated

The USA-2 on the summit

The ultrasonic sensor measures the summit’s wind, and the gusts the forecast office asks for. The treasurer chose it in place of a second cup anemometer, whose bearings ice over on a winter night. The borrowed unit is mounted on the new mast’s arm beside its heater.toml, read by ridged as --sensor usa2, and reported all 2,880 readings of the storm night (mneme://4410).

Options, the treasurer’s call

  1. Keep it and extend the loan: one more winter, one sensor at a time.
  2. Buy the lender’s spare, and keep the cup anemometer on --fallback cups for the nights the sensor goes quiet.
  3. Replace it with a sensor the network can service itself.
$ ridge probe --sensor usa2 --port /dev/ttyUSB0 --station summit --night 2026-03-03
USA-2 ultrasonic, firmware 3.11
  rate 4 Hz  heater on  rime 0.0 mm
  missing 0 of 2,880

Rests on

reftitlestate
mneme://4410The borrowed USA-2 reported all 2,880 readings of the storm night at 4 Hz, its heater on throughoutlive
bldr://4211Price a second ultrasonic sensor when the lender’s spare comes up for sale, to pair with the cupstriage
perdix://4302stations/sensor-probe.pyfrozen

Discussion

treasurer

Decided: buy the lender’s spare for the summit. The valley stations stay on cup anemometers and --fallback cups, since a heater on every mast would drain the batteries and slow the readings on a cold night.