Ridgeline’s second summit mast (proposal)

What there is today

Read from the base unit’s log on 2026-03-14, the morning after the storm, at the logger’s 4e1c9a2, the tip of main and of origin/main.

What reads the mast from outside the network.

The network has two anemometers.

the cup anemometerthe ultrasonic sensor (USA-2)
mountedat 10 m, on the old mastat 12 m, on the new mast’s arm
readsspeed by counting the cups’ turns, and the gust as the fastest three-second count, in gust_kphspeed and direction from the time sound takes between its faces: u, v and w at 4 Hz
powerthe solar panel alone, 0.4 Wa 12 V battery and its heater, 2.1 W to 9.5 W in rime
failswhen its bearings ice, quietly reading lowwhen rime covers its faces, by reporting nothing
read bythe forecast officethe logger’s ridged, the trailhead board and the forecast office
checkednoagainst the airport’s mast 14 km away: within 4 % on 212 windy days (mneme://1076)

What is decided already.

1. The heater runs on a timer; ridged keeps one clock

The treasurer’s push-back, 2026-03-14:

I plan for the summit to hold quite a bit of kit through the winter. I am looking to run the heater, the camera and the rain gauge from one battery, which means things like schedules, alarms and a reserve for the dark weeks are things I’m looking to plan for. Would running all of it from the hut’s bank be feasible?

Revised, and decided: the heater runs on a timer. Left to its thermostat it is feasible, and it is weakest exactly where the readings matter.

Bringing a station up to date

The logger reads its settings once at start, so a copied file by itself changes nothing that is running:

ridge pull
ridge verify
ridge restart station-4
ridge backfill --station summit --from 2026-03-03T22:00 --to 2026-03-04T06:00 --source raw/2026-03-03.bin