Ridgeline’s second summit mast (proposal)
What there is today
Read from the base unit’s log on 2026-03-14, the morning after the storm, at the logger’s 4e1c9a2, the tip of main and of origin/main.
What reads the mast from outside the network.
- The forecast office’s pull fetches
summit.csvandvalley.csv, every column, fromhttps://ridgeline.example/data/. - The trailhead board wants
https://ridgeline.example/nowto answer (its ownconfig/sources.json). - No other station’s code reads a file beneath it.
- In the base unit’s logs, nothing ever requested
/data/archive.zip./nowhad 2,113 requests, named crawlers among them.
The network has two anemometers.
| the cup anemometer | the ultrasonic sensor (USA-2) | |
|---|---|---|
| mounted | at 10 m, on the old mast | at 12 m, on the new mast’s arm |
| reads | speed by counting the cups’ turns, and the gust as the fastest three-second count, in gust_kph | speed and direction from the time sound takes between its faces: u, v and w at 4 Hz |
| power | the solar panel alone, 0.4 W | a 12 V battery and its heater, 2.1 W to 9.5 W in rime |
| fails | when its bearings ice, quietly reading low | when rime covers its faces, by reporting nothing |
| read by | the forecast office | the logger’s ridged, the trailhead board and the forecast office |
| checked | no | against the airport’s mast 14 km away: within 4 % on 212 windy days (mneme://1076) |
What is decided already.
- The mast proposal, mneme://3619:
- the new mast is the network’s own and replaces the borrowed one;
- it is built from the kit’s parts (
<mast>,boom,shield, guy wires, a lightning rod), with the network’s code for about ten alarms; - a reading every ten minutes, with the forecast office’s floor of 98 % complete days;
- at the base unit, the same logger as every station: the summit is a station like any other.
- The power proposal, mneme://3814: the mast draws on the hut’s battery bank at
hut.ridgeline.example, charged by the hut’s turbine, under the hut’s own fuse. None of it is wired: its Step 5 waits for “the first dry weekend after the thaw.”
1. The heater runs on a timer; ridged keeps one clock
The treasurer’s push-back, 2026-03-14:
I plan for the summit to hold quite a bit of kit through the winter. I am looking to run the heater, the camera and the rain gauge from one battery, which means things like schedules, alarms and a reserve for the dark weeks are things I’m looking to plan for. Would running all of it from the hut’s bank be feasible?
Revised, and decided: the heater runs on a timer. Left to its thermostat it is feasible, and it is weakest exactly where the readings matter.
Bringing a station up to date
The logger reads its settings once at start, so a copied file by itself changes nothing that is running:
ridge pull
ridge verify
ridge restart station-4
ridge backfill --station summit --from 2026-03-03T22:00 --to 2026-03-04T06:00 --source raw/2026-03-03.bin